SDC 2002
3. Operational Preparations
3-6
Operating Instructions - Rev. 1 / 6.2003
3.4. USER-SPECIFIC CONFIGURATION OF THE FILM SCANNER
3.4.1. CHANGE OPTICAL BLOCK
Changing the optical block (Super16mm, Super35mm/FA 35mm LGA - Lens
Gate Assembly) optically matches the film scanner to the wanted film format.
1. Remove the threaded film from the optical block, if necessary.
2. Unlock the optical block (LGA, lens gate assembly).
For this purpose, move the locking lever on the right of the optical block in up-
wards ccw direction.
3. Seize the optical block at the two handles, pull it out on its guide rails and re-
move it.
Attention! When pulling out the optical block, keep a firm hold on it (approx. 8 kg)!
As soon as the optical block leaves the guide rails, it might be possible that
it slides downwards.
4. Set the new optical block on the guide rails and slide it slowly towards the film
deck plate until it fits.
5. Lock again the lever beside the optical block (position LOCK).
6. Open the film gate locking lever and close it again, to ensure, that the film gate
is not tilt.
7. Perform FPN correction (see section 3.5.).