SDC 2002
6. Maintenance
6-2
Operating Instructions - Rev. 1 / 6.2003
Cleaning and
maintenance intervals
prior to each
film threading
every
4-8 weeks
quarterly
semi-annu-
ally
every
3-5 years
see
section
COMOPT sound optics X 6.6.
LGA air filter change X 6.8.
Filter mats, blowers X
6.8.,
6.9.
Backup battery X 6.10.
6.1. SAFETY INSTRUCTIONS
Before performing maintenance and service routines, switch off the film
scanner SDC 2002 and disconnect it from the mains by switching off the cir-
cuit breaker at the Power Terminal Unit (3-Phase) FH 6030 or (1-Phase)
FH 1032!
Prior to starting cleaning routines on the drive mechanism, optical block, capstan
roller or audio scanner, make sure that no film is threaded.
For cleaning, always wear gloves and use clean, lint-free
cleaning cloths (order no. 5 001 310 280)
and isopropyl alcohol (order no. 5 108 701 008)
If work is required close to the xenon projector lamp housing, do not start work-
ing before it has cooled down for 30 minutes - risk of getting burnt.
Caution!
High intensity ultraviolet energy exists within the illumination path, gener-
ated by the Xenon arc lamp.
Protect eyes and skin.
For cleaning the capstan roller use isopropyl alcohol only, never acetone!
Please see also the safety instructions of the customer’s manual.
Attention!
Ultraviolet
Radiation
Komentarze do niniejszej Instrukcji