SDC 2002
4.9 Special Menu
4-183
Operating Instructions - Rev. 1 / 6.2003
8. Buttons for Reference Set & Reset
9. Area of film type refence hole (P or N) and selection of reference perforation
hole for a 35mm image
Detailed descriptions see the next paragraphs!
Details of Function Buttons, Controls & Displays
1. Operation
mode
Operation
Selects Steadiscan operation mode
Pausing
no Steadiscan correction is performed
Running Steadiscan is working
2. Status
Operating
&
Frame Store
Delay
4 frames
Operating status
shows the Steadiscan operating status:
pausing no Steadiscan correction is performed
running Steadiscan is working
adjusting appears during adjustment of perf offset or ruler area
not initialized appears during Steadiscan initialization
Frame store delay shows the SDC signal delay
1 frame without Steadiscan operation
4 frames if Steadiscan is running
The frame store delay, compensating the computing time of Steadiscan, is auto-
matically switched on and off by the Film Deck Controller depending on wether
Steadiscan is running or not.
Frame store delay depending on Steadiscan- and SDC operation:
frame store delay
(field 2 )
Steadiscan op - status
(field 3)
SDC
op - modes
1 frame pausing stop, reverse
4 frame running film speed 6.25 fps forw.