SDC 2002
6. Maintenance
6-25
Operating Instructions - Rev. 1 / 6.2003
10. Press button “Manufacturing only”
A numeric keypad menu is displayed.
Enter ”1996” on the numeric keypad of the control panel. The service
mode is active now.
11. Select “Channel 1/2 Level“
Compensate the level loss of the COMOPT sound using the adjust dial on the
control panel.
With 35mm adjust to 0 dBu
and with 16mm adjust to +4 dBu
at the film scanner output AUDIO 1/2 (terminal panel rack 1).
Subsequently press “Close” button to store the adjustments as unity values
(default values).
Select section “Pre-Adjust again for the following equalizer adjustment.
12. Thread a 16mm or 35mm comopt sound frequency response film in the film
scanner.
16mm comopt frequency response film order no.: SMPTE P16-MF
35mm comopt frequency response film order no.: SMPTE P35-MF
13. Start play on the film scanner.
14. After selecting “Channel 1/2 Equalizer” adjust with the digipot control the fre-
quency response to optimum at the film scanner output AUDIO 1/2.
adjust with 16mm to 2 dB
and adjust with 35mm to 1 dB
Subsequently press button “Close” to store the adjustments as unity values
(default values).
15. Adjust to the original used studio level again.
That means readjust the adjustment of item xxxx to the original value.