6. Maintenance
6-5
Operating Instructions - Rev. 1 / 6.2003
6.2.2. CLEAN THE CAPSTAN ROLLER
Caution!
Clean the capstan roller only in stop mode! Risk of injury!
Capstan roller
Audio scanner: option
Fig.604: Capstan roller
A dirty capstan roller causes picture instability.
1. Remove the film from the film deck.
2. Switch off the film scanner
3. Clean the complete capstan roller surface thoroughly removing all deposits
with a isopropyl alcohol moistened cleaning cloth.
Avoid excessive force on the roller surface!
As a cleaning agent, use only isopropyl alcohol and a lint-free cleaning
cloth!
Removing the capstan or changing its position affects the picture steadiness,
therefore any work on the capstan should be done by Thomson service personnel
only.
Attention!