SDC 2002
6. Maintenance
6-18
Operating Instructions - Rev. 1 / 6.2003
1st possibility of change:
The first possibility of changing the projection lamp is to change the complete lamp
housing.
See section 6.3.1., which explains the required operational steps.
Order no.:
Lamp housing, cpl. FH 1921 0 128 192 110 new version
0 128 192 190 exch. version
(incl. Xenon-projection lamp)
2nd possibility of change:
change the projection lamp with heat sink
(order n o. 3 119 100 267)
1. Remove the lamp housing (see section 6.3.1.).
Caution! Allow to cool for 30 minutes before removing the door.
29855
Connection cables
Lamp housing
Door
Spring-loaded latch
Projection lamp
Heat sink
Direction of projection
Fig. 616: : Lamp housing (opened)
The following works must not be carried out without protective goggles
and protection gloves. Danger of implosion!
2. Open the spring-loaded latches of the lamp housing and tilt the case lid up-
wards (see Fig. 616: ).
3. Remove both connection cables from the heat sinks.
Note the mounting position of the heat sinks.
4. Pull the heat sinks together with the projection lamp out of the case.
ATTENTION: